---
product_id: 163545951
title: "50ml Stainless Steel Hydrothermal Synthesis Autoclave Reactor,Digestion high-Pressure Tank with Teflon Lining PTFE Lined for Rapid Digestion of Insoluble Material"
brand: "fcx"
price: "5475324₫"
currency: VND
in_stock: false
category: "BISS"
url: https://www.desertcart.vn/products/163545951-50ml-stainless-steel-hydrothermal-synthesis-autoclave-reactor-digestion-high-pressure
store_origin: VN
region: Vietnam
---

# 50ml Stainless Steel Hydrothermal Synthesis Autoclave Reactor,Digestion high-Pressure Tank with Teflon Lining PTFE Lined for Rapid Digestion of Insoluble Material

**Brand:** fcx
**Price:** 5475324₫
**Availability:** ❌ Out of Stock

## Quick Answers

- **What is this?** 50ml Stainless Steel Hydrothermal Synthesis Autoclave Reactor,Digestion high-Pressure Tank with Teflon Lining PTFE Lined for Rapid Digestion of Insoluble Material by fcx
- **How much does it cost?** 5475324₫ with free shipping
- **Is it available?** Currently out of stock
- **Where can I buy it?** [www.desertcart.vn](https://www.desertcart.vn/products/163545951-50ml-stainless-steel-hydrothermal-synthesis-autoclave-reactor-digestion-high-pressure)

## Best For

- fcx enthusiasts

## Why This Product

- Trusted fcx brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Description

1. High temperature resistance: Teflon material actual measuring operating temp. is higher than 220&#x2103;, advise safe operating temp. &#x2264; 220&#x2103;.  2. Low temperature resistance: -196&#x2103; could keep 5%. 3. Ultra corrosion resistance: resistant to strong acid, strong base, aqua regia and all kinds of organic solvent. 4. Insulation resistance: dielectric properties have nothing to do with temperature and frequency. 5. High lubrication: the friction coefficient of solid materials is lowest. 6. No adhesion: don&apos;t adhere to any material, self lubricity is strong, the friction coefficient of solid materials is 0.04. 7. Non hazardous: has physiologically inert, can be embedded in human body, strong aging resistance, guarantee hydrothermal synthesis reactor long service life. 8. Anti-pollution: the baseline value of metallic element is low, lead content <10-11g/ml, uranium content <10-12g/ml. How to use it : The reaction means and the reactor body, and to ensure feeding coefficient is less than 0.8.  When the Department of corrosive reaction when you want to put PTFE bush, can only be assured kettle body from corrosion.  Hydrothermal synthesis reactor will be placed on the heater, in accordance with the provisions of the heating rate of heating to the desired reaction temperature (less than the required safety temperature).  Completion of the reaction will be when its cool, but also in strict accordance with the provisions of the cooling rate operation, to facilitate the safety and reactor life.  When confirmation of intra-abdominal temperature below the boiling point solvents reaction system can only open the tank lid after a follow-up operation.  Hydrothermal synthesis reactor each time after use to clean, to avoid corrosion.

## Images

![50ml Stainless Steel Hydrothermal Synthesis Autoclave Reactor,Digestion high-Pressure Tank with Teflon Lining PTFE Lined for Rapid Digestion of Insoluble Material - Image 1](https://m.media-amazon.com/images/I/41xaYed6G-L.jpg)
![50ml Stainless Steel Hydrothermal Synthesis Autoclave Reactor,Digestion high-Pressure Tank with Teflon Lining PTFE Lined for Rapid Digestion of Insoluble Material - Image 2](https://m.media-amazon.com/images/I/41qFXf5rO6L.jpg)
![50ml Stainless Steel Hydrothermal Synthesis Autoclave Reactor,Digestion high-Pressure Tank with Teflon Lining PTFE Lined for Rapid Digestion of Insoluble Material - Image 3](https://m.media-amazon.com/images/I/31t6CpS+mjL.jpg)
![50ml Stainless Steel Hydrothermal Synthesis Autoclave Reactor,Digestion high-Pressure Tank with Teflon Lining PTFE Lined for Rapid Digestion of Insoluble Material - Image 4](https://m.media-amazon.com/images/I/41xaYed6G-L.jpg)
![50ml Stainless Steel Hydrothermal Synthesis Autoclave Reactor,Digestion high-Pressure Tank with Teflon Lining PTFE Lined for Rapid Digestion of Insoluble Material - Image 5](https://m.media-amazon.com/images/I/41WewHQdrjL.jpg)

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.vn/products/163545951-50ml-stainless-steel-hydrothermal-synthesis-autoclave-reactor-digestion-high-pressure](https://www.desertcart.vn/products/163545951-50ml-stainless-steel-hydrothermal-synthesis-autoclave-reactor-digestion-high-pressure)

---

*Product available on Desertcart Vietnam*
*Store origin: VN*
*Last updated: 2026-05-21*